Designing for low pitch roofs - 2.5 Formal CPD Points

The delivery of waterproof and durable long-span low pitch roofs is a key issue in many industrial, commercial, and public buildings. Research shows that waterproofing defects remain one of the key sources of aggravation for building owners and occupiers and this often spills over into disputes and legal action. 
 
Planning height constraints, architectural considerations and cost management are just some of the key reasons that encourage the use of low pitch roofs. 
 
As a result, long span metal deck roofing in Australia and New Zealand is often designed and installed at the minimum pitch recommended by the manufacturer, which can be as low as one degree.
 
This compares with traditional rules of thumb used by architects, building designers, builders and engineers that suggested a minimum pitch of 3 degrees on steel and 4 degrees on timber structures as being the lowest practical pitch to avoid ponding and leaks at junctions, particularly where the roof is frequently accessed for maintenance without the benefit of a separate walkway structure. 
 
Although the Australian National Construction Code, the New Zealand Building Code and Australian and NZ Standards permit low roof pitches with metal deck roofing providing they are approved by the manufacturer, this Mecca webinar examines how architects, building designers, hydraulic engineers and roofing contractors can deliver low pitched roofs with adequate performance and durability, and happy clients down the track. 

Our team of experts will discuss issues and solutions including:

  1. Do membrane roofs, which are common in Europe and the US, offer a realistic alternative to low pitch metal deck roofs and in what circumstances might they be considered?

  2. Do siphonic drainage solutions offer benefits in Australian conditions, particularly as horizontal drainage runs can be flat and therefore can be contained within the depth of the roof structure?

  3. Are roll-on-site metal deck solutions superior to the alternative of using standard lengths. What are the pros and the cons?

  4. Control of condensation and mould on the underside of low pitch roofing, including insulation and vapour barriers. 

  5. Insulation and sustainability.

  6. Design of roof penetrations at low pitches; issues and solutions.  

  7. Should planning rules on height be reformed to focus on effective height rather than overall height where overshadowing and sightlines are not key considerations, allowing the use of higher pitches and deeper roof structures?

  8. Low pitched roofs may reduce embodied energy, but is this sufficient to counter other sustainability issues that may arise?

  9. Resolving roof drainage design and roof drainage maintenance on taller buildings where access to eaves gutters may be problematic.

  10. Rain noise issues with metal deck roofing.

  11. Designing the next generation of concrete flat roofs. Warm roof systems and exposed concrete ceilings.

Our Expert Presenters/Panel

Daniel Jakobs

pro clima

Daniel Jakobs is a qualified master carpenter and construction engineer from Germany. With more than 20 years’ experience in high performance and ecological building, Daniel is the Technical Sales Manager for pro clima in Australia and New Zealand. With an in-depth knowledge of pro clima’s entire international product range and performance characteristics, he is able to develop pragmatic weatherproofing and airtightness solutions for any building type. Daniel is also responsible for the practical knowledge transfer and training of builders and tradespeople in Australia and New Zealand, focusing on the pro clima product range but also teaching skills necessary for building structures to world leading Passive House standard. Daniel was instrumental in the construction of the pro clima HUB – Centre for Advanced Building Systems in Auckland, delivering a world class facility.

Horaci Sanchez

Six Degrees

With over 24 years’ experience, Horaci has been involved in all stages of diverse projects in Australia, the U.S. and Spain. Horaci’s experience ranges across all scales of residential to high rise commercial, museums and aquariums. Horaci brings an expertise in the delivery of large projects, particularly residential, commercial, and a breadth of design experience from all over the globe. In his role as Associate Director and Design manager at Six Degrees, Horaci is charged with managing an open and creative Design process, to draw the best expertise and experience to all projects, and drive an innovative, thoughtful and collaborative design strategy.

Geoff Hanmer

Arina Architects

Geoff is an Adjunct Professor of Architecture at the University of Adelaide, and Honorary Professional Fellow at UTS and the Managing Director of Arina, an architectural consultancy. ARINA has run design competitions for many Australian universities (including UNSW) and statutory authorities, including the Sydney Cove Redevelopment Authority. Geoff is a registered architect and writes on construction and buildings both contemporary and historical. He has taught and researched construction at UTS and UNSW for over 20 years.

CPD - Participation in this webinar will deliver 2.5 formal CPD points.

Written CPD questions will be circulated with your purchase. Send your responses to CPD questions to mark@meccaevents.com.au for the issue of a certificate of completion. Keep your receipt, completed questions and certificate for your CPD records.


For more information, contact Mark Gledhill - mark@meccaevents.com.au

Developing a Reconciliation Plan for your Business
A$110.00
What does a Climate conscious future look like?
A$110.00
Understanding the Indigenous Voice to Parliament
A$80.00
Industrial Manslaughter and Due Diligence
A$110.00
Reducing Global Emissions in Building ... Is Passive House the Answer?
A$110.00